Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 9 de 9
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
3.
Infect Control Hosp Epidemiol ; 44(8): 1361-1364, 2023 08.
Artigo em Inglês | MEDLINE | ID: mdl-36177872

RESUMO

Contaminated shoes are a potential vector for dissemination of healthcare-associated pathogens. We demonstrated that healthcare personnel walking into patient rooms frequently transferred pathogens from their shoes to the floor. An 8-second treatment of shoes with a UV-C decontamination device significantly reduced the frequency of transfer of vegetative bacterial pathogens.


Assuntos
Quartos de Pacientes , Raios Ultravioleta , Humanos , Contagem de Colônia Microbiana , Bactérias , Descontaminação
4.
Am J Infect Control ; 51(6): 714-717, 2023 06.
Artigo em Inglês | MEDLINE | ID: mdl-36195154

RESUMO

We demonstrated that methicillin-resistant Staphylococcus aureus (MRSA) contamination on floors in the rooms of colonized long-term care facility residents was frequently transferred by shoes to adjacent patient rooms. A benign virus inoculated onto the floor was transferred to floors and high-touch surfaces in adjacent rooms and the nursing station. These results suggest that shoes may serve as a vector for dissemination of health care-associated pathogens from rooms of MRSA-colonized patients.


Assuntos
Infecção Hospitalar , Staphylococcus aureus Resistente à Meticilina , Infecções Estafilocócicas , Humanos , Levivirus , Staphylococcus aureus , Assistência de Longa Duração , Resistência a Meticilina , Infecções Estafilocócicas/prevenção & controle , Quartos de Pacientes , Infecção Hospitalar/prevenção & controle
6.
Pathog Immun ; 7(2): 66-77, 2022.
Artigo em Inglês | MEDLINE | ID: mdl-36381131

RESUMO

Reprinted with permission, Cleveland Clinic Foundation ©2022. All Rights Reserved. Background: Barriers are commonly installed in workplace situations where physical distancing cannot be maintained to reduce the risk for transmission of respiratory viruses. Although some types of barriers have been shown to reduce exposure to aerosols in laboratory-based testing, limited information is available on the efficacy of barriers in real-world settings. Methods: In an acute care hospital, we tested the effectiveness of in-use plexiglass barriers in reducing exposure of staff to aerosolized particles. A nebulizer was used to release 5% NaCl aerosol 1 meter from staff members with and without the barrier positioned between the point of aerosol release and the hospital staff. Particle counts on the staff side of the barrier were measured using a 6-channel particle counter. A condensed moisture (fog) generating device was used to visualize the airflow patterns. Results: Of 13 in-use barriers tested, 6 (46%) significantly reduced aerosol particle counts detected behind the barrier, 6 (46%) reduced particle counts to a modest, non-significant degree, and 1 (8%) significantly increased particle counts behind the barrier. Condensed moisture fog accumulated in the area where staff were seated behind the barrier that increased particle exposure, but not behind the other barriers. After repositioning the ineffective barrier, the condensed moisture fog no longer accumulated behind the barrier and aerosol exposure was reduced. Conclusion: In real-world settings, plexiglass barriers vary widely in effectiveness in reducing staff exposure to aerosols, and some barriers may increase risk for exposure if not positioned correctly. Devices that visualize airflow patterns may be useful as simple tools to assess barriers.

7.
PLoS Genet ; 18(9): e1010200, 2022 09.
Artigo em Inglês | MEDLINE | ID: mdl-36074769

RESUMO

SARS-CoV-2 whole genome sequencing has played an important role in documenting the emergence of polymorphisms in the viral genome and its continuing evolution during the COVID-19 pandemic. Here we present data from over 360 patients to characterize the complex sequence diversity of individual infections identified during multiple variant surges (e.g., Alpha and Delta). Across our survey, we observed significantly increasing SARS-CoV-2 sequence diversity during the pandemic and frequent occurrence of multiple biallelic sequence polymorphisms in all infections. This sequence polymorphism shows that SARS-CoV-2 infections are heterogeneous mixtures. Convention for reporting microbial pathogens guides investigators to report a majority consensus sequence. In our study, we found that this approach would under-report sequence variation in all samples tested. As we find that this sequence heterogeneity is efficiently transmitted from donors to recipients, our findings illustrate that infection complexity must be monitored and reported more completely to understand SARS-CoV-2 infection and transmission dynamics. Many of the nucleotide changes that would not be reported in a majority consensus sequence have now been observed as lineage defining SNPs in Omicron BA.1 and/or BA.2 variants. This suggests that minority alleles in earlier SARS-CoV-2 infections may play an important role in the continuing evolution of new variants of concern.


Assuntos
COVID-19 , COVID-19/genética , Genoma Viral/genética , Humanos , Pandemias , SARS-CoV-2/genética
9.
Pathog Immun ; 7(2): 120-130, 2022.
Artigo em Inglês | MEDLINE | ID: mdl-36655199

RESUMO

Background: Inadequate ventilation may contribute to the high risk for household transmission of severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2). Methods: We evaluated the effectiveness of several interventions recommended to improve ventilation in households. In 7 residential homes, carbon dioxide monitoring was conducted to assess ventilation in occupied open areas such as family rooms and in bedrooms and/or offices. Carbon dioxide levels above 800 parts per million (ppm) were considered an indicator of suboptimal ventilation for the number of people present. In 1 of the 7 homes, various interventions to improve ventilation or to filter air were assessed in a kitchen area by measuring clearance of aerosol particles produced using an aerosol-based spray system and carbon dioxide generated by cooking with a gas stove. Results: Carbon dioxide levels rose above 800 ppm in bedrooms and offices with 2 occupants when windows and doors were closed and in open areas during gatherings of 5 to 10 people; carbon dioxide levels decreased when windows or doors were opened. Clearance of carbon dioxide and aerosol particles significantly increased with interventions including running fans, operating portable air cleaners, and opening windows, particularly when there was a noticeable breeze or when a window fan was used to blow contaminated air outside. Conclusion: In households, several measures to improve ventilation or air filtration were effective in reducing carbon dioxide accumulation or enhancing clearance of carbon dioxide and aerosol particles. Studies are needed to determine if interventions to improve ventilation can reduce the risk for airborne transmission of SARS-CoV-2 in households.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...